8 kW TO 400 kw

ULTIMATE UPS SOLUTION - providing uninterrupted power and protection against noise, lightning, and leakage current.

LED, HID, Incandescent, Fluorescent

Installed in Computer Rooms, Production Facilities, Testing Labs, Telecommunications, Industrial, Government Buildings, Public Buildings, Schools, Healthcare, Cruise & Cargo Ships, Banking, Printing Facilities.

WAVE RIDER 4 - HYBRID

FEATURES

ETL Certified to UL1778 and UL924
True Galvanic Isolation design
Designed to protect against a floating neutral
Advanced digital signal processing
Modular design for ease of troubleshooting and maintenance
Redundant multi-CPU design allows the software and hardware to work together as a team
The most intelligent and safe battery test circuitry available today
Individualized inverter support on each phase
Intelligent, fully temperature compensated battery charger
Hi-tech fan speed control
Optimum design for heat dissipation
Battery Power start feature
2 Year Limited Factory Warranty

 

SPECIFICATIONS

Power Rating 8, 16, 24, 32, 40, 48, 64, 80, 96, 128, 160, 192, 240, 320, and 400kW
Input Voltage 208Y/120 or 480Y/277 VAC (-15% to +15%)
Output Voltage 208Y/120 or 480Y/277 VAC
Output Frequency 60Hz ±7Hz (Inverter Operation)
Output Voltage Reg. ±1% at 100% unbalanced load
Output Waveform Sine-wave <2% THD
Crest Factor 3.1 Typical
Surge Protection The UPS will protect itself and the load against surge as defined in ANSI/IEEE C62.41 category A and B.
Isolation True galvanic isolated
Battery Sealed maintenance-free VRLA or Long Life Battery (available upon request)
Recharge Time Varies per KVA and conforms to UL924
Environmental

Humidity: 0-95% RH w/no condensation
Operating Temperature:
UPS: 0°C to 40°C. (32°F to 104°F)
Battery: 20°C to 30°C. (68°F to 86°F)
Storage temperature: -20°C to 60°C. (-40°F to 140°F)

Safety Agencies ETL Certified to UL1778 and UL924, NFPA, NEC, OSHA.

 

Document Files
Document Type PDF format Word Format
DatasheetDatasheet
Design Guide SpecDesign Guide SpecDesign Guide Spec
ManualManual
Tech DrawingsTech Drawings
Seismic BracketSeismic Bracket
OptionsOptionsOptions
STP/CAD Files

Standard

Cabinet TypeKVA / SizeMountingFile
Inverter Cabinet (63"H)10 - 60 KVAStandardSTP
Inverter Cabinet (63"H)80 - 160 KVAStandardSTP
Battery CabinetC SizeStandardSTP
Battery CabinetD SizeStandardSTP

With Seismic

Cabinet TypeKVA / SizeMountingFile
Inverter Cabinet (63"H)10 - 60 KVAWith SeismicSTP
Inverter Cabinet (63"H)80 - 160 KVAWith SeismicSTP
Battery CabinetC SizeWith SeismicSTP
Battery CabinetD SizeWith SeismicSTP